Home > Product
On-line potassium ion detector

On-line potassium ion detector

The ion sensor can realize the flexible selection of one or two ion selection electrodes, and the default standard PH and temperature electrodes, realizing simultaneously monitoring the four parameters. The optional parameters of the ion selection electrode include: ammonium ion (NH4 +), nitrate ion (NO3-), potassium ion (K +), chloride ion (CL-), and fluoride ion (F-). Different parameter combinations can also realize the role of mutual compensation, making the measurement data more accurate.

CONTACT WECHAT:18156665555
description

measuring principle

The ion sensor can realize the flexible selection of one or two ion selection electrodes, and the default standard PH and temperature electrodes, realizing simultaneously monitoring the four parameters. The optional parameters of the ion selection electrode include: ammonium ion (NH4 +), nitrate ion (NO3-), potassium ion (K +), chloride ion (CL-), and fluoride ion (F-). Different parameter combinations can also realize the role of mutual compensation, making the measurement data more accurate.

 

functional characteristics

Choose one or two electrodes in ammonium ion, nitrate ion, potassium ion, chloride ion or fluoride ion. Realize flexible combination to meet the needs of different customers.

Digital sensor, strong anti-interference ability, the transmission distance is long;

Standard digital signal output, which can be integrated and networked with other devices without a transmitter;

Sensor site installation is convenient and fast, to achieve plug and play;

Sensor power supply positive and negative electrode reverse connection protection, sensor RS485 A / B terminal misconnection power supply protection;

With time display, data storage and historical data viewing function;

Optional data wireless transmission module.

 

 Typical application

Monitor ammonia nitrogen and nitronitrogen in surface water, groundwater, industrial processes and sewage treatment.

 

Sensing technical parameter

Sensing technical parameter
measuring range (NH4N):0.1~1000 mg/L
(NO3N):0.5~1000 mg/L
(K+):0.5~1000 mg/L
(CL-):3~1000 mg/L
(F-):0.5~1000 mg/L
 PH:5-10     tempreture:0~40℃
resolution ratio Ion parameters:0.01mg/L
tempreture:0.1℃
ph:0.01
measurement accuracy Other ion parameters :± 10% of the measured value or ±0.2 mg/L Temperature :± 0.5℃ pH:±0.1 pH
repeatability ±5% or 0.2mg/1 Max
communication protocol MODBUS RS485
storage temperature 0 to 50 ° C (no freezing)
working temperature 0 to 40 ° C (no freezing)
size 55mm×342mm(diameter × length)
weight <1KG
level of protection IP68/NEMA6P
cable length 0 m cable is standard and can be extended up to 100 m

 

Controller parameters

Model MDS-KP500
Display 4.3 inches, 480*800 resolution, 262K color, IPS screen, wide viewing Angle, with backlight
  Capacitive touch screen with three protection processes (moisture-proof, mildew proof, salt spray proof)
Display size 95.0mm*53.9mm
Measuring range -99999.0000~99999.0000
Password Protection The default password is 0000
Compatible sensor Digital sensor
Mounting method Disk mounting (with chassis), wall-mounted mounting
Alarm relay 2 relays can set high and low alarm
Current output 2 isolated 4-20mA, maximum load 750Q, can be set
Communication port RS485 Modbus RTU
Memory backup All user Settings are stored indefinitely in EERPOM
historical data The storage capacity of 8000 points is recorded at a 5-minute interval
Operating environment -10~+50℃,0~95% relative humidity, no condensation
Storage environment -20 to +70 ° C,0 to 95% relative humidity, non-condensing
The power supply 12V±10%
Power consumption of the instrument less than 6W
Instrument size 144X145X85(mm)
Protection class IP65
Contact us
ADD:J2C, Phase II, Hefei Innovation Industrial Park, Anhui, China
Wechat:18156665555
Email:JAMES@MADSURGROUP.COM
Oline Chat
All rights reserved © Copyright 2025 MADSUR