Calcium ion selective electrode has the advantages of simple measurement and fast and accurate response. It can be used with PH meter, ionometer and on-line calcium ion analyzer. It is also used in the ion selective electrode detector of electrolyte analyzer and flow injection analyzer.Calcium ion-selective electrode is an effective method to measure the calcium ion content in a sample. Calcium ion-selective electrodes are also often used in on-line instruments, such as industrial on-line monitoring of calcium ion content.
CONTACT WECHAT:18156665555Calcium ion-selective electrode is an effective method to measure the calcium ion content in a sample. Calcium ion-selective electrodes are also often used in on-line instruments, such as industrial on-line monitoring of calcium ion content.
Calcium ion selective electrode has the advantages of simple measurement and fast and accurate response. It can be used with PH meter, ionometer and on-line calcium ion analyzer. It is also used in the ion selective electrode detector of electrolyte analyzer and flow injection analyzer.
Application:
calcium ion determination of calcium ion selection electrode method in feed water treatment of high pressure steam boiler in power plant and steam power plant; calcium ion selective electrode method to determine calcium ions in mineral water, drinking water, surface water and seawater; calcium ion selective electrode method to determine calcium ions in tea, honey, feed, milk powder and other agricultural products; calcium ion selective electrode method in saliva, serum, urine and other biological samples.
Sensing technical parameter
gradient | 26 ± 2 mV 25 °C |
repetitiveness | ± 2% |
disturb | Pb 2+ , Hg 2+ , Cu 2+ , Ni 2+ |
temperature range | 0-50°C |
pressure limit | 0-2 atm |
response speed | In 30 seconds to reach a 95% response |
lay in | Long-term: dry preservation; |
Short-term: stored in a diluted calcium standard solution | |
measuring range | 0.2 ppm – 40,000 ppm |
PH range | 3 – 10 pH |
output impedence | 20-50MΩ |
Maintenance and cleaning | First with deionized water, followed by a diluted calcium standard solution |
temperature compensation | 10k/22k//2.252K/PT1000/PT100 Optional |
on line operation | can |
isopotential point | 1 ppm Ca 2+ |
reference electrode | Double salt bridge, single hole ceramic liquid boundary. |
material quality | PMMA+PVC |
connect | terminal |
apply | Mineral springs, drinking water; industrial circulating water; waste water; surface water; sea water; |
Ore; soil; food; biological fluids, blood clinical analysis of calcium ions, calcium content detection |
Controller parameters
Model | MDS-KP500 |
Display | 4.3 inches, 480*800 resolution, 262K color, IPS screen, wide viewing Angle, with backlight |
Capacitive touch screen with three protection processes (moisture-proof, mildew proof, salt spray proof) | |
Display size | 95.0mm*53.9mm |
Measuring range | -99999.0000~99999.0000 |
Password Protection | The default password is 0000 |
Compatible sensor | Digital sensor |
Mounting method | Disk mounting (with chassis), wall-mounted mounting |
Alarm relay | 2 relays can set high and low alarm |
Current output | 2 isolated 4-20mA, maximum load 750Q, can be set |
Communication port | RS485 Modbus RTU |
Memory backup | All user Settings are stored indefinitely in EERPOM |
historical data | The storage capacity of 8000 points is recorded at a 5-minute interval |
Operating environment | -10~+50℃,0~95% relative humidity, no condensation |
Storage environment | -20 to +70 ° C,0 to 95% relative humidity, non-condensing |
The power supply | 12V±10% |
Power consumption of the instrument | less than 6W |
Instrument size | 144X145X85(mm) |
Protection class | IP65 |