The ion sensor can realize the flexible selection of one or two ion selection electrodes, and the default standard PH and temperature electrodes, realizing simultaneously monitoring the four parameters. The optional parameters of the ion selection electrode include: ammonium ion (NH4 +), nitrate ion (NO3-), potassium ion (K +), chloride ion (CL-), and fluoride ion (F-). Different parameter combinations can also realize the role of mutual compensation, making the measurement data more accurate.
CONTACT WECHAT:18156665555measuring principle
The ion sensor can realize the flexible selection of one or two ion selection electrodes, and the default standard PH and temperature electrodes, realizing simultaneously monitoring the four parameters. The optional parameters of the ion selection electrode include: ammonium ion (NH4 +), nitrate ion (NO3-), potassium ion (K +), chloride ion (CL-), and fluoride ion (F-). Different parameter combinations can also realize the role of mutual compensation, making the measurement data more accurate.
functional characteristics
Choose one or two electrodes in ammonium ion, nitrate ion, potassium ion, chloride ion or fluoride ion. Realize flexible combination to meet the needs of different customers.
Digital sensor, strong anti-interference ability, the transmission distance is long;
Standard digital signal output, which can be integrated and networked with other devices without a transmitter;
Sensor site installation is convenient and fast, to achieve plug and play;
Sensor power supply positive and negative electrode reverse connection protection, sensor RS485 A / B terminal misconnection power supply protection;
With time display, data storage and historical data viewing function;
Optional data wireless transmission module.
Typical application
Monitor ammonia nitrogen and nitronitrogen in surface water, groundwater, industrial processes and sewage treatment.
Sensing technical parameter
Sensing technical parameter | |
measuring range | (NH4N):0.1~1000 mg/L |
(NO3N):0.5~1000 mg/L | |
(K+):0.5~1000 mg/L | |
(CL-):3~1000 mg/L | |
(F-):0.5~1000 mg/L | |
PH:5-10 tempreture:0~40℃ | |
resolution ratio | Ion parameters:0.01mg/L tempreture:0.1℃ ph:0.01 |
measurement accuracy | Other ion parameters :± 10% of the measured value or ±0.2 mg/L Temperature :± 0.5℃ pH:±0.1 pH |
repeatability | ±5% or 0.2mg/1 Max |
communication protocol | MODBUS RS485 |
storage temperature | 0 to 50 ° C (no freezing) |
working temperature | 0 to 40 ° C (no freezing) |
size | 55mm×342mm(diameter × length) |
weight | <1KG |
level of protection | IP68/NEMA6P |
cable length | 0 m cable is standard and can be extended up to 100 m |
Controller parameters
Model | MDS-KP500 |
Display | 4.3 inches, 480*800 resolution, 262K color, IPS screen, wide viewing Angle, with backlight |
Capacitive touch screen with three protection processes (moisture-proof, mildew proof, salt spray proof) | |
Display size | 95.0mm*53.9mm |
Measuring range | -99999.0000~99999.0000 |
Password Protection | The default password is 0000 |
Compatible sensor | Digital sensor |
Mounting method | Disk mounting (with chassis), wall-mounted mounting |
Alarm relay | 2 relays can set high and low alarm |
Current output | 2 isolated 4-20mA, maximum load 750Q, can be set |
Communication port | RS485 Modbus RTU |
Memory backup | All user Settings are stored indefinitely in EERPOM |
historical data | The storage capacity of 8000 points is recorded at a 5-minute interval |
Operating environment | -10~+50℃,0~95% relative humidity, no condensation |
Storage environment | -20 to +70 ° C,0 to 95% relative humidity, non-condensing |
The power supply | 12V±10% |
Power consumption of the instrument | less than 6W |
Instrument size | 144X145X85(mm) |
Protection class | IP65 |