The selective electrode of the on-line nitrate ion detector is an effective method to measure the nitrate ion content in samples. Nitrate ion-selective electrodes are also often used in on-line instruments, such as industrial on-line monitoring of nitrate ion content.Nitrate ion-selective electrode, which has the advantage of simple measurement, fast and accurate response, and can be used with PH meter, ion meter and on-line nitrate ion analyzer.
CONTACT WECHAT:18156665555The selective electrode of the on-line nitrate ion detector is an effective method to measure the nitrate ion content in samples. Nitrate ion-selective electrodes are also often used in on-line instruments, such as industrial on-line monitoring of nitrate ion content.
Nitrate ion-selective electrode, which has the advantage of simple measurement, fast and accurate response, and can be used with PH meter, ion meter and on-line nitrate ion analyzer.
Application:
nitrate ion selection electrode method for measuring nitrate concentration in solid waste leaching solution; nitrate ion selective electrode method for measuring nitrate ion in coal and ore; nitrate ion selective electrode method for measuring nitrate ions in soil; nitrate ion selective electrode method for detecting nitrate ion in rainfall and surface water; nitrate ion selective electrode method for measuring nitrate ions in vegetables, preserved products and other agricultural products.
Sensing technical parameter
gradient | 55± 3mv |
repetitiveness | ± 2% |
disturb | And ClO 4-1, I-1, CN-1, BF 4-1, Cl-, NO2-, and organic acid ions |
temperature range | 0-50°C |
pressure limit | 0-2 atm |
response speed | In 30 seconds to reach a 95% response |
lay in | Long-term: dry preservation; |
Short term: stored in diluted nitrate standard solution | |
measuring range | 0.5ppm –62,000ppm |
PH range | 2.5-11PH |
output impedence | 20-50MΩ |
Maintenance and cleaning | Deionized water was treated with a diluted standard nitrate solution |
temperature compensation | 10k/22k//2.252K/PT1000/PT100 Optional |
on line operation | can |
isopotential point | 10 ppm NO3- |
reference electrode | Double salt bridge, single hole ceramic liquid boundary. |
material quality | PMMA+PVC |
connect | terminal |
apply | Drinking water; waste water; surface water; seawater; ore; soil; food; detection of nitrate ions in boiler circulating water |
Controller parameters
Model | MDS-KP500 |
Display | 4.3 inches, 480*800 resolution, 262K color, IPS screen, wide viewing Angle, with backlight |
Capacitive touch screen with three protection processes (moisture-proof, mildew proof, salt spray proof) | |
Display size | 95.0mm*53.9mm |
Measuring range | -99999.0000~99999.0000 |
Password Protection | The default password is 0000 |
Compatible sensor | Digital sensor |
Mounting method | Disk mounting (with chassis), wall-mounted mounting |
Alarm relay | 2 relays can set high and low alarm |
Current output | 2 isolated 4-20mA, maximum load 750Q, can be set |
Communication port | RS485 Modbus RTU |
Memory backup | All user Settings are stored indefinitely in EERPOM |
historical data | The storage capacity of 8000 points is recorded at a 5-minute interval |
Operating environment | -10~+50℃,0~95% relative humidity, no condensation |
Storage environment | -20 to +70 ° C,0 to 95% relative humidity, non-condensing |
The power supply | 12V±10% |
Power consumption of the instrument | less than 6W |
Instrument size | 144X145X85(mm) |
Protection class | IP65 |